Product Description

Innovation
1.  Five steps temperature control program, setting rate from 0.1~40º/min, can be setted arbitrary, time setting range: 9999.9min.
2.  Three detectors(TCD+FID) can be setted on the instrument simultaneously. Detector's gas flow controllers use combination valves, to get realiblity.
3.  Bright LCD display, can display all of the patements, e. G. Temperature, pressure and gas flow.
4.  Use new type control technique, It is one of the top grade standard chromatograph.
Index of temperature controller
1. GC1690 is using big capacity column oven, and is designed vertical structure to reduce heat radiation of injectors and detectors. Have Five steps temperature control program, raise and cooling rapidly, suitable to high boiling point sample's analysis.
2. Temperature control range: Room temperature +15º to 399º.
3. Precision of temperature: ±0.1º
Parameter of technique
1. Precision of temperature control: ±0.1º
2. Rate: 0.1~40º/min
3. Flame Ionization Detector(FID) sensitivity: Mt¡Ü1*10-11g/s
4. Thermal Conductivity Detector(TCD) sensitivity: S¡Ý2500mV. Ml/mg

Index of technique
1. Column oven
High capacity column oven: 14600cm3, precision of temperature: ±0.1º C. Five steps temperature control program, temperature gradient: ±1%, temperature control program rate: 0.1~40º/min, time setting range: 9999.9min.
2. Other temperature control sections
Five sections: TCD, DET, INJ, AUX1, AUX2
Temperature control range: Room temperature +8º to 399º
Precision of temperature: ±0.1º
3. Power supply
220V±10% a. C, 50/60Hz
Power: 2000W
4. Index of detector
Thermal conductivity etector(TCD)
Sensitivity: S¡Ý2500mV. Ml/mg
Drift: ¡Ü100UV/30min
Noise: ¡Ü20UV
Linerity: ¡Ý10000
Suit to:
Organic chemical compound constant analysis;
Inorganic chemical compound and gas trace analysis.
Flame ionization detector(FID)
Sensitivity: Mt¡Ü1*10-11 g/s
Drift: ¡Ü2*10-12A/30min
Noise: ¡Ü2*10-13 A
Linerity: ¡Ý1000000
Suit to:
Organic chemical compound constant and trace analysis
Characteristic
1. Microcomputer control, high precision of temperature control, (superior to ± 0.1º).
2. Parameters of control can be setted from keyboard, functions of maxium temperature and system dead protection.
3. Fixed 450º protection circuit, maxium protection temperature can be setted from keyboard, system dead protection.
4. The equipmemt has two inject sections and gas flow lines, use high accurate valves to get high stability and reappearance.
5. The equipmemt is suitable packed column and capillary coulmn. There are several inject sections.
Packed column: Coulmn inject, vaporization inject, gas inject.
Capillary coulmn: Split, spiltless, 0.53mm wide bore capillary directly inject.
6. Automatic cooling door system, cooling rapidly.